<LOGO>
FM Transmitter Measurement Report
Created: 2026-01-18 15-53-17
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 3/5, 37 dBuV SANDELS
Pilot RDS Phase Difference
5.9 kHz 4.9 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
15 kHz 22 kHz 4290 0,0466
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,2 dBr 4,49 dBr 6,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 22 kHz MIN: 15 kHz % above 76 kHz: 0,0466 Acquired: 2026/01/18 15.52.11 Total samples: 4290 Equivalent time: 0:03:34 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300
FM Scope MAX: 6,2 dBr MIN: 3,2 dBr AVE: 4,49 dBr % above 12,2 dBr: 0,0 Last value: 3,4 dBr (2026/01/18 15.52.11) 15.38 15.40 15.42 15.44 15.46 15.48 15.50 15.52 0 2 4 6 Pm [dBr]